Following are but a few of the home inspection summary comments made by home inspectors for our clients when evaluating the client's prospective purchase:
"Cracks were observed in the roofing cement used to seal the roof shingles and the plumbing vents. These cracks
should be sealed in order to prevent the penetration of water through the openings. This condition should be
repaired as soon as possible and is considered a maintenance item which should be performed on a periodic
basis."
"The Ground Fault Interrupter (G. F. I.) receptacle in the rear upstairs
bedroom does not respond to manufactures testing device. Replacement of
the receptacle is recommended."
"The furnace exhaust pipe is resting against the 2 x 4 wall stud and the 2 x 6 ceiling joist in the furnace closet
on the second floor. According to the exhaust pipe manufacturers instructions, at least one inch must be
maintained between the exhaust pipe and any combustible material. I recommend removing the wall stud and
bypassing the ceiling joist in order to provide adequate clearance for the exhaust pipe. This condition is a
safety concern."
"The mortar on top of the chimney is cracked and deteriorating. The mortar chimney cap is the first line of
defense against rainwater penetrating the bricks and mortar in the chimney. Water can deteriorate the mortar
and cause structural damage to the chimney. I recommend patching the mortar cap."
"Moderate dampness from water penetration was observed along the front and left (east) wall of the basement.
This moisture and water penetration appears to be the result of gutters on the left front of the house depositing
water at the front of the basement and the grade (ground) sloping toward the foundation wall on the left side of
the house. I recommend installing downspouts to the gutters on the front and rear of the house and resloping
the grade away from the house."
"The front door unit is not securely fasted to the slab at the threshold. This condition has caused the door
casing to move at the threshold when opening and closing. This condition has also caused the door not to
seal properly against the weather-stripping at the top when closed. Securing of the threshold to the slab is
recommended." (Former Parade of Homes exhibit)
"The fan in the upper most portion of the attic does not respond to
activation of the thermostat control. The fan blade, which is mounted
directly on the motor shaft, will not turn. This condition indicates that
the motor is burned out and should be replaced."
"The plywood roof sheathing is damaged on the left side of the chimney. This decay is the result of a past roof
leak. The damaged section of the sheeting is approximately 12" by 24" and has caused a sag in the roof shingles
adjacent to the chimney. I recommend replacing the damaged sheathing. Deterioration of the exterior wood
fascia and delamination of the soffit was observed on the left side of the chimney, also the result of the prior leak.
It appears the leak has been repaired, however, the decayed trim was not replaced. Replacement of this damaged
wood is recommended."
"The following conditions were observed with the water heater in the attic: Heavy rust around the bottom of the
heater, rust and standing water in the drain pan, the exhaust pipe is not properly aligned with the draft diverter,
and the unit has tilted and is not setting level. It appears that a leak in the tank has caused the rust to form and
has deteriorated the base of the heater. This condition has caused the heater to tilt....I recommend replacement
of the water heater."